Exfo IQS-2600B Tunable Laser Source for IQS Platforms Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Exfo IQS-2600B Tunable Laser Source for IQS Platforms. EXFO IQS-2600B Tunable Laser Source for IQS Platforms User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - IQS-2600B

User GuideTunable Laser Source for IQS PlatformsIQS-2600B

Página 2

Introducing the IQS-2600B Tunable Laser Source4 IQS-2600BConventionsConventionsBefore using the product described in this manual, you should understan

Página 3 - Contents

SCPI Command Reference94 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:CYCLe?Description This query returns the number

Página 4

SCPI Command ReferenceTunable Laser Source 95Product-Specific Commands—DescriptionResponse(s) Cycle: The response data syntax for <Cycle> is def

Página 5

SCPI Command Reference96 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:DIRectionDescription This command controls the d

Página 6 - DECLARATION OF CONFORMITY

SCPI Command ReferenceTunable Laser Source 97Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:DIRection?Description This query retu

Página 7 - 1 Introducing the IQS-2600B

SCPI Command Reference98 IQS-2600BProduct-Specific Commands—DescriptionONEWAY, the sweep is performed in one direction, from start to stop.TWOWAY, the

Página 8 - Typical Applications

SCPI Command ReferenceTunable Laser Source 99Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:REPeatDescription This command is use

Página 9 - Tunable Laser Source 3

SCPI Command Reference100 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:REPeat?Description This query returns the sweep

Página 10 - IMPORTANT

SCPI Command ReferenceTunable Laser Source 101Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STARtDescription This command allows

Página 11 - 2 Safety Information

SCPI Command Reference102 IQS-2600BProduct-Specific Commands—DescriptionDEFault allows the instrument to select a value for the <StartWavelength>

Página 12

SCPI Command ReferenceTunable Laser Source 103Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STARt?Description This query returns

Página 13 - Tunable Laser Source

Tunable Laser Source 52 Safety InformationWhile handling optical fibers, laser radiation may be encountered at source output ports and fiber ends. Avo

Página 14 - 8 IQS-2600B

SCPI Command Reference104 IQS-2600BProduct-Specific Commands—DescriptionResponse(s) StartWavelength: The response data syntax for <StartWavelength&

Página 15 - Retaining screw knob

SCPI Command ReferenceTunable Laser Source 105Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STOPDescription This command allows

Página 16 - 10 IQS-2600B

SCPI Command Reference106 IQS-2600BProduct-Specific Commands—DescriptionExample(s) SOUR:WAV:SWE:STOP 0.00000155 (if current unit is meter)SOUR:WAV:SWE

Página 17 - (white background)

SCPI Command ReferenceTunable Laser Source 107Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STOP?Description This query returns

Página 18 - 12 IQS-2600B

SCPI Command Reference108 IQS-2600BProduct-Specific Commands—DescriptionResponse(s) StopWavelength: The response data syntax for <StopWavelength>

Página 19 - Status Bar

SCPI Command ReferenceTunable Laser Source 109Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:SPEedDescription This command allows

Página 20 - 14 IQS-2600B

SCPI Command Reference110 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:SPEed?Description This query returns the sweep

Página 21 - Exiting the Application

SCPI Command ReferenceTunable Laser Source 111Product-Specific Commands—DescriptionResponse(s) Speed: The response data syntax for <Speed> is de

Página 22

SCPI Command Reference112 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STATeDescription This function starts or stops

Página 23 - 4 Setting Standard Parameters

SCPI Command ReferenceTunable Laser Source 113Product-Specific Commands—DescriptionExample(s) UNIT:SPEC MSOUR:WAV:SWE:REP CONTSOUR:WAV:SWE:STAR 0.0000

Página 25 - Selecting the Display Unit

SCPI Command Reference114 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STATe?Description This query returns a value in

Página 26 - Selecting a Wavelength

SCPI Command ReferenceTunable Laser Source 115Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:TIME?Description This query returns

Página 27

SCPI Command Reference116 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STEP[:WIDTh]Description This command allows you

Página 28 - Setting the Power

SCPI Command ReferenceTunable Laser Source 117Product-Specific Commands—DescriptionExample(s) SOUR:WAV:SWE:STEP 0.00000001SOUR:WAV:SWE:STEP 1.6NMNotes

Página 29 - Using the Slider

SCPI Command Reference118 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:STEP[:WIDTh]?Description This query returns the

Página 30 - Adding Items to Lists

SCPI Command ReferenceTunable Laser Source 119Product-Specific Commands—DescriptionResponse(s) StepWidth: The response data syntax for <StepWidth&g

Página 31 - Deleting Items from Lists

SCPI Command Reference120 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:DWELlDescription This command allows you to set

Página 32 - 26 IQS-2600B

SCPI Command ReferenceTunable Laser Source 121Product-Specific Commands—DescriptionExample(s) SOUR:WAV:SWE:DWEL 550MSNotes This function cannot be per

Página 33

SCPI Command Reference122 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:DWELl?Description This query returns the time i

Página 34

SCPI Command ReferenceTunable Laser Source 123Product-Specific Commands—DescriptionResponse(s) DwellTime: The response data syntax for <DwellTime&g

Página 35 - 5 Setting Sweep Parameters

Tunable Laser Source 73 Getting Started with Your Tunable Laser SourceInserting and Removing Test ModulesTo insert a module into the controller or exp

Página 36 - Selecting the Sweep Mode

SCPI Command Reference124 IQS-2600BProduct-Specific Commands—Description:TRIGger[1..n][:SEQuence]:INPutDescription This command allows you to set the

Página 37 - Using the Stepped Mode

SCPI Command ReferenceTunable Laser Source 125Product-Specific Commands—Description:TRIGger[1..n][:SEQuence]:INPut?Description This query returns the

Página 38 - 32 IQS-2600B

SCPI Command Reference126 IQS-2600BProduct-Specific Commands—Description:UNIT[1..n]:SPECtrumDescription This command allows you to set the spectrum un

Página 39 - Setting the Cycle Options

SCPI Command ReferenceTunable Laser Source 127Product-Specific Commands—Description:UNIT[1..n]:SPECtrum?Description This query returns the current spe

Página 41

Tunable Laser Source 129C Trigger Option TheoryYour Tunable Laser Source features Trigger In and Out connectors. When the trigger option is set to On,

Página 42 - 36 IQS-2600B

Trigger Option Theory130 IQS-2600BTrigger Option in Stepped ModeTrigger Option in Stepped ModeThe sweep will begin when you press on Start. The system

Página 43

IndexTunable Laser Source 131IndexAAbout function tab ... 58adding items on the current lists... 24adj

Página 44

Index132 IQS-2600BIidentification label ... 57identification, slot ... 13increm

Página 45 - Starting a Sweep

IndexTunable Laser Source 133selectingdisplay unit... 19from a stored list ...

Página 46

Getting Started with Your Tunable Laser Source8 IQS-2600BInserting and Removing Test Modules4. Insert the protruding edges of the module into the groo

Página 47 - Laser Source

NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT

Página 48 - Using Monitor Windows

MARKING REQUIREMENTS㪖㽷尐㻑Productℶ❐Environmental protection use period (years)䘾⬒≬㔳∎䞷㦮棟 ( ㄃ )Logo㪖㉦This Exfo product㦻 EXFO ℶ❐10Batterya䟄㻯aa. If applicabl

Página 49

www.EXFO.com · [email protected]/N: 1062026CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-

Página 50 - Using QuickTools

Getting Started with Your Tunable Laser SourceTunable Laser Source 9Inserting and Removing Test ModulesThe module is correctly inserted when its front

Página 51

Getting Started with Your Tunable Laser Source10 IQS-2600BInserting and Removing Test Modules3. Cover empty slots with the supplied protective covers.

Página 52

Getting Started with Your Tunable Laser SourceTunable Laser Source 11Starting the Tunable Laser Source ApplicationStarting the Tunable Laser Source Ap

Página 53 - 8 Maintenance

Getting Started with Your Tunable Laser Source12 IQS-2600BStarting the Tunable Laser Source ApplicationNote: Pressing the LED push button will not act

Página 54

Getting Started with Your Tunable Laser SourceTunable Laser Source 13Starting the Tunable Laser Source ApplicationTitle BarThe title bar is located at

Página 55

ii IQS-2600BCopyright © 2003–2011 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transm

Página 56

Getting Started with Your Tunable Laser Source14 IQS-2600BEntering Values Using Sliders and Numeric BoxesEntering Values Using Sliders and Numeric Box

Página 57

Getting Started with Your Tunable Laser SourceTunable Laser Source 15Exiting the ApplicationExiting the ApplicationClosing any application that is not

Página 59

Tunable Laser Source 174 Setting Standard ParametersThe standard parameters are set through the Instrument function tab.

Página 60 - Recycling and Disposal

Setting Standard Parameters18 IQS-2600BSwitching between Normal and High-Resolution (HR) ModesSwitching between Normal and High-Resolution (HR) ModesY

Página 61 - 9 Troubleshooting

Setting Standard ParametersTunable Laser Source 19Selecting the Display UnitSelecting the Display UnitIt is possible to select the display unit with w

Página 62 - Viewing Online Documentation

Setting Standard Parameters20 IQS-2600BSelecting a WavelengthSelecting a WavelengthThere are several ways to select a wavelength for testing.Whenever

Página 63 - IQS-2600B-XX-XX

Setting Standard ParametersTunable Laser Source 21Selecting a WavelengthRetrieving a Wavelength from a Stored ListTo select a wavelength from the list

Página 64 - 58 IQS-2600B

Setting Standard Parameters22 IQS-2600BSetting the PowerSetting the PowerThere are several ways to select a power value for testing.Whenever you use c

Página 65 - Transportation

Setting Standard ParametersTunable Laser Source 23Setting the PowerRetrieving Power Step Value from a Stored ListTo select a power step value from the

Página 66

ContentsTunable Laser Source iiiContentsCertification Information ...

Página 67 - 10 Warranty

Setting Standard Parameters24 IQS-2600BAdding Items to ListsAdding Items to ListsYou can add items to the current Wavelength Presets, Wavelength Step,

Página 68 - Certification

Setting Standard ParametersTunable Laser Source 25Deleting Items from ListsDeleting Items from ListsYou can delete items from the current Wavelength P

Página 69 - Service and Repairs

Setting Standard Parameters26 IQS-2600BSaving and Recalling ConfigurationsSaving and Recalling ConfigurationsOnce you have set the IQS-2600B Tunable L

Página 70 - 64 IQS-2600B

Setting Standard ParametersTunable Laser Source 27Saving and Recalling ConfigurationsTo recall a configuration:1. Select the Configuration function ta

Página 72 - GENERAL SPECIFICATIONS

Tunable Laser Source 295 Setting Sweep ParametersYour Tunable Laser Source allows you to perform automatic wavelength scans according to user-defined

Página 73 - Technical Specifications

Setting Sweep Parameters30 IQS-2600BSetting a Delay for the SweepSetting a Delay for the SweepA delay at the beginning of a sweep can allow you to coo

Página 74

Setting Sweep ParametersTunable Laser Source 31Selecting the Sweep ModeUsing the Stepped ModeTo select the Stepped sweep mode, click the appropriate b

Página 75 - B SCPI Command Reference

Setting Sweep Parameters32 IQS-2600BSelecting the Incoming Trigger OptionSelecting the Incoming Trigger OptionThe incoming trigger option allows you t

Página 76 - Quick Reference Command Tree

Setting Sweep ParametersTunable Laser Source 33Setting the Cycle OptionsSetting the Cycle OptionsThe cycle options allow you to specify settings in bo

Página 77

Contentsiv IQS-2600B7 Monitoring Your Tunable Laser Source ...41Using Monitor Windows ...

Página 78 - :ABORt[1..n]

Setting Sweep Parameters34 IQS-2600BSetting the Sweep DirectionSetting the Sweep DirectionThe sweep can be either unidirectional, meaning that it will

Página 79 - :CALibration[1..n]:WAVelength

Tunable Laser Source 356 Operating your Tunable Laser SourceCleaning and Connecting Optical FibersTo connect the fiber-optic cable to the port:1. Insp

Página 80

Operating your Tunable Laser Source36 IQS-2600BCleaning and Connecting Optical Fibers3. Carefully align the connector and port to prevent the fiber en

Página 81 - :INITiate[1..n][:IMMediate]

Operating your Tunable Laser SourceTunable Laser Source 37Installing the EXFO Universal Interface (EUI)Installing the EXFO Universal Interface (EUI)Th

Página 82 - 76 IQS-2600B

Operating your Tunable Laser Source38 IQS-2600BActivating/Deactivating Light EmissionActivating/Deactivating Light EmissionBefore turning on the Tunab

Página 83 - Tunable Laser Source 77

Operating your Tunable Laser SourceTunable Laser Source 39Starting a SweepStarting a SweepAfter setting your sweep parameters as explained in Setting

Página 85

Tunable Laser Source 417 Monitoring Your Tunable Laser SourceWhen using your IQS-2600B Tunable Laser Source module, either alone or with other modules

Página 86 - [:IMMediate][:AMPLitude]?

Monitoring Your Tunable Laser Source42 IQS-2600BUsing Monitor WindowsTo select modules and display their monitor windows:1. On the Current Modules fun

Página 87

Monitoring Your Tunable Laser SourceTunable Laser Source 43Using Monitor WindowsClosemonitorwindowRearrangemonitorsin columnsRepositionmonitor windows

Página 88 - :SOURce[1..n]:POWer:STATe

Certification InformationTunable Laser Source vCertification InformationFCC InformationElectronic test equipment is exempt from Part 15 compliance (FC

Página 89 - :SOURce[1..n]:POWer:STATe?

Monitoring Your Tunable Laser Source44 IQS-2600BUsing QuickToolsUsing QuickToolsWith QuickTools, you can fine-tune your module directly, while keeping

Página 90 - :SOURce[1..n]:WAVelength[:CW]

Monitoring Your Tunable Laser SourceTunable Laser Source 45Using QuickToolsTo c lo se Qui ck Tool s:Click the Close button located at the top of the

Página 92 - 86 IQS-2600B

Tunable Laser Source 478 MaintenanceTo help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them and clean th

Página 93 - Example(s) SOUR:WAV?

Maintenance48 IQS-2600BCleaning Fixed ConnectorsCleaning Fixed ConnectorsRegular cleaning of connectors will help maintain optimum performance. Do not

Página 94 - :SOURce[1..n]:WAVelength:MODE

MaintenanceTunable Laser Source 49Cleaning Fixed Connectors7. Slowly insert the cleaning tip into the connector until it reaches the ferrule inside (a

Página 95 - Tunable Laser Source 89

Maintenance50 IQS-2600BCleaning EUI ConnectorsCleaning EUI ConnectorsRegular cleaning of EUI connectors will help maintain optimum performance. There

Página 96 - 90 IQS-2600B

MaintenanceTunable Laser Source 51Cleaning EUI Connectors5. Repeat steps 3 to 4 with a dry cleaning tip.Note: Make sure you don’t touch the soft end o

Página 97 - Tunable Laser Source 91

Maintenance52 IQS-2600BAdjusting Your Unit According to WavelengthAdjusting Your Unit According to WavelengthIt is possible to introduce an offset in

Página 98 - 92 IQS-2600B

MaintenanceTunable Laser Source 53Adjusting Your Unit According to WavelengthThe difference between the pre-selected wavelength and the measured wavel

Página 99 - Tunable Laser Source 93

Certification Informationvi IQS-2600BPage 1 of 1 DECLARATION OF CONFORMITY Application of Council Directive(s): 2006/95/EC ± The Low Voltage Direc

Página 100 - 94 IQS-2600B

Maintenance54 IQS-2600BRecalibrating the UnitRecalibrating the UnitManufacturing and service center calibrations are based on the ISO/IEC 17025 Standa

Página 101 - Tunable Laser Source 95

Tunable Laser Source 559 TroubleshootingSolving Common ProblemsIf you encounter one of the problems listed below, try to solve it first with the given

Página 102 - DIRection

Troubleshooting56 IQS-2600BViewing Online DocumentationViewing Online DocumentationAn online version of the IQS-2600B Tunable Laser Source user guide

Página 103 - DIRection?

TroubleshootingTunable Laser Source 57Contacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or tec

Página 104

Troubleshooting58 IQS-2600BContacting the Technical Support GroupYou may also be requested to provide software and module version numbers.This informa

Página 105 - Tunable Laser Source 99

TroubleshootingTunable Laser Source 59TransportationTransportationMaintain a temperature range within specifications when transporting the unit. Trans

Página 107 - Tunable Laser Source 101

Tunable Laser Source 6110 WarrantyGeneral InformationEXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship for a period

Página 108 - 102 IQS-2600B

Warranty62 IQS-2600BExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of any of its products at any time witho

Página 109 - Tunable Laser Source 103

WarrantyTunable Laser Source 63Service and RepairsService and RepairsEXFO commits to providing product service and repair for five years following the

Página 110 - 104 IQS-2600B

Tunable Laser Source 11 Introducing the IQS-2600B Tunable Laser SourceGeneral InformationThe IQS-2600B Tunable Laser Source addresses the testing requ

Página 111 - Tunable Laser Source 105

Warranty64 IQS-2600BEXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact your nearest authorized se

Página 112 - 106 IQS-2600B

Tunable Laser Source 65A Technical SpecificationsIMPORTANTThe following technical specifications can change without notice. The information presented

Página 113 - Tunable Laser Source 107

Technical Specifications66 IQS-2600BGENERAL SPECIFICATIONSOutput fiber type SMF-28Operating temperature 10 °C to 40 °C (50 °F to 104 °F)Storag

Página 114 - 108 IQS-2600B

Technical SpecificationsTunable Laser Source 67WAVELENGTHRange (nm) 1510 to 1612Display resolution (pm) 1Effective spectral linewidth FWHMb (GHz) 1

Página 115 - Tunable Laser Source 109

Technical Specifications68 IQS-2600BGENERAL SPECIFICATIONSOutput fiber type SMF-28Operating temperature 10 °C to 40 °C (50 °F to 104 °F)Storag

Página 116 - 110 IQS-2600B

Tunable Laser Source 69B SCPI Command ReferenceThis appendix presents detailed information on the commands and queries supplied with your IQS-2600B Tu

Página 117 - Tunable Laser Source 111

SCPI Command Reference70 IQS-2600BQuick Reference Command TreeQuick Reference Command TreeCommand Parameter(s) P.ABORt[1..n] 72CALibration[1..n]WAVele

Página 118 - 112 IQS-2600B

SCPI Command ReferenceTunable Laser Source 71Quick Reference Command TreeREPeat CONTinuous|NCONtinuous 99REPeat? 100STARt <StartWavelength[<wsp&

Página 119 - Tunable Laser Source 113

SCPI Command Reference72 IQS-2600BProduct-Specific Commands—DescriptionProduct-Specific Commands—Description:ABORt[1..n]Description This command is us

Página 120 - 114 IQS-2600B

SCPI Command ReferenceTunable Laser Source 73Product-Specific Commands—Description:CALibration[1..n]:WAVelengthDescription This command introduces an

Página 121 - Tunable Laser Source 115

Introducing the IQS-2600B Tunable Laser Source2 IQS-2600BTypical Appl ication sThe IQS-2600B Tunable Laser Source supports local control (via the IQS

Página 122 - STEP[:WIDTh]

SCPI Command Reference74 IQS-2600BProduct-Specific Commands—DescriptionExample(s) SOUR:POW:STATE ON- Wait for the power on operation to be complete.SO

Página 123

SCPI Command ReferenceTunable Laser Source 75Product-Specific Commands—Description:INITiate[1..n][:IMMediate]Description This function starts the swee

Página 124 - STEP[:WIDTh]?

SCPI Command Reference76 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:POWer:ALC[:STATe]Description This command activates the laser out

Página 125

SCPI Command ReferenceTunable Laser Source 77Product-Specific Commands—Description:SOURce[1..n]:POWer:ALC[:STATe]?Description This query returns state

Página 126 - 120 IQS-2600B

SCPI Command Reference78 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:POWer[:LEVel][:IMMediate][:AMPLitude]Description This command set

Página 127 - SCPI Command Reference

SCPI Command ReferenceTunable Laser Source 79Product-Specific Commands—DescriptionExample(s) SOUR:POW:LEV:IMM:AMPL -6.35SOUR:POW -1.25Notes This funct

Página 128 - 122 IQS-2600B

SCPI Command Reference80 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:POWer[:LEVel][:IMMediate][:AMPLitude]?Description This query retu

Página 129 - Tunable Laser Source 123

SCPI Command ReferenceTunable Laser Source 81Product-Specific Commands—DescriptionResponse(s) OutputPower: The response data syntax for <OutputPowe

Página 130 - 124 IQS-2600B

SCPI Command Reference82 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:POWer:STATeDescription This command turns the optical source on o

Página 131 - Tunable Laser Source 125

SCPI Command ReferenceTunable Laser Source 83Product-Specific Commands—Description:SOURce[1..n]:POWer:STATe?Description This query returns a value ind

Página 132 - :UNIT[1..n]:SPECtrum

Introducing the IQS-2600B Tunable Laser SourceTunable Laser Source 3IQS-2600CT Tunable Laser Source for IQS-12004B DWDM Passive Component Test SystemI

Página 133 - :UNIT[1..n]:SPECtrum?

SCPI Command Reference84 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength[:CW]Description This command selects the source's

Página 134

SCPI Command ReferenceTunable Laser Source 85Product-Specific Commands—DescriptionExample(s) SOUR:WAV 0.00000155SOUR:WAV 1550NMSOUR:WAV MAXNotes This

Página 135 - C Trigger Option Theory

SCPI Command Reference86 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength[:CW]?Description This query returns the output wavelen

Página 136 - 130 IQS-2600B

SCPI Command ReferenceTunable Laser Source 87Product-Specific Commands—DescriptionExample(s) SOUR:WAV?Notes This function cannot be performed while th

Página 137 - Tunable Laser Source 131

SCPI Command Reference88 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:MODEDescription This command is used to toggle between

Página 138

SCPI Command ReferenceTunable Laser Source 89Product-Specific Commands—Description:SOURce[1..n]:WAVelength:MODE?Description This query returns the cur

Página 139 - Tunable Laser Source 133

SCPI Command Reference90 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:MODEDescription This command allows you to selec

Página 140 - ₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩

SCPI Command ReferenceTunable Laser Source 91Product-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:MODE?Description This query returns t

Página 141 - MARKING REQUIREMENTS

SCPI Command Reference92 IQS-2600BProduct-Specific Commands—Description:SOURce[1..n]:WAVelength:SWEep:CYCLeDescription This command specifies the numb

Página 142

SCPI Command ReferenceTunable Laser Source 93Product-Specific Commands—DescriptionExample(s) SOUR:WAV:SWE:REP NCONSOUR:WAV:SWE:CYCL 32Notes This funct

Comentários a estes Manuais

Sem comentários