User GuideCopper Test SetMaxTester MAX-610
Introducing the MaxTester MAX-6102 MAX-610Typical ApplicationsTypical Applications Auto tests including POTS Auto Test Multimeter tests Noise tests
MaxTester Copper Test 937 Multimeter TestsThe purpose of the multimeter tests function is to detect AC/DC voltages and currents, and measure resistanc
Multimeter Tests94 MAX-610VoltageVoltageThe Voltage test detects AC RMS and DC voltages in the line and allows you to measure AC/DC voltages and Frequ
Multimeter TestsMaxTester Copper Test 95VoltageTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2. Pr
Multimeter Tests96 MAX-610VoltageContinuous AC PageThe Continuous AC function measures each pair, displaying and updating results in real time, until
Multimeter TestsMaxTester Copper Test 97VoltageTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2. Pr
Multimeter Tests98 MAX-610Voltage Result displays a snapshot of the pass/fail status and volts for each continuous DC pair. Test Status displays th
Multimeter TestsMaxTester Copper Test 99CurrentCurrentThe Current test allows you to measure the AC/DC currents and frequency in the loop.SnapshotThe
Multimeter Tests100 MAX-610CurrentTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2. Press the left/
Multimeter TestsMaxTester Copper Test 101CurrentContinuous AC PageThe Continuous AC function measures each pair, displaying and updating results in re
Introducing the MaxTester MAX-610MaxTester Copper Test 3Using the MAX-610 Right FrontDC Power DoorUSB Client Port Power LEDBattery LED Speaker
Multimeter Tests102 MAX-610CurrentTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2. Press the left/
Multimeter TestsMaxTester Copper Test 103Current Result displays a snapshot of the pass/fail status and DC current results for each selected wire pai
Multimeter Tests104 MAX-610ResistanceResistanceThe Resistance test, also know as shorts, allows you to measure the current resistance value and cable
Multimeter TestsMaxTester Copper Test 105ResistanceTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2
Multimeter Tests106 MAX-610ResistanceContinuousThe Continuous function measures each pair, displaying and updating results in real time, until you sto
Multimeter TestsMaxTester Copper Test 107Resistive BalanceTo select the parameter values:1. Press the up/down arrow keys to highlight the desired para
Multimeter Tests108 MAX-610Resistive Balance Threshold Settings button opens a new page that allows you to set the resistive balance thresholds. Tes
Multimeter TestsMaxTester Copper Test 109Resistive BalanceResult DetailsThe Results Details read-only page displays the Resistance results for each le
Multimeter Tests110 MAX-610IsolationIsolationThe Isolation test, also known as leakage, allows you to run a resistance test over a period of time to l
Multimeter TestsMaxTester Copper Test 111Isolation Result displays a snapshot of the pass/fail status, Resistance and a Soak Counter for each selecte
Introducing the MaxTester MAX-6104 MAX-610Using the MAX-610 BackNote: The MAX-610 enclosure may become warm during normal use.Battery DoorScrewsScrew
Multimeter Tests112 MAX-610Isolation3. Press on a value to open a list box of options or the alphanumeric editor screen and use the navigation keys
Multimeter TestsMaxTester Copper Test 113Isolation Result displays a snapshot of the pass/fail status, Resistance and a Soak Counter for each selecte
Multimeter Tests114 MAX-610Capacitance/OpensCapacitance/OpensThe Capacitance/Opens test measures the capacitance of the loop and calculates length. Ca
Multimeter TestsMaxTester Copper Test 115Capacitance/Opens Capacitance T/R to GND displays the capacitance value from Tip or Ring to Ground, in nF/mi
Multimeter Tests116 MAX-610Capacitance/OpensNote: The accuracy of the 2 Terminal Capacitance Measurement is impacted by the use of the FED, and the 3
Multimeter TestsMaxTester Copper Test 117Capacitance/OpensCapacitance/Opens Threshold SettingsThe Threshold Settings page allows you to set the Capaci
Multimeter Tests118 MAX-610Station GroundStation GroundThe Station Ground test measures and displays the resistance value and pass/fail status of the
Multimeter TestsMaxTester Copper Test 119Station Ground The Confirmation window is prompted before every Station Ground test is started if you select
Multimeter Tests120 MAX-610Station GroundThreshold SettingsThe Test Thresholds page allows you to set the threshold values for the Ground Resistance.
Multimeter TestsMaxTester Copper Test 121Stressed BalanceStressed BalanceThe Stressed Balance is an option enabled test that continuously generates hi
Introducing the MaxTester MAX-610MaxTester Copper Test 5Cable ConnectionsCable ConnectionsThe graphics below show the connectors on the MAX-610 device
Multimeter Tests122 MAX-610Stressed BalanceThreshold SettingsThe Threshold Settings page allows you to set the Good/Marginal Balance threshold values
Multimeter TestsMaxTester Copper Test 123Stressed BalanceResult DetailsThe Result Details read-only page displays the Stressed Balance results and the
MaxTester Copper Test 1258 SmartR™ FeaturesSmartR features, consisting of Pair Detective and FaultMapper, allow you to determine the condition of the
SmartR™ Features126 MAX-610Pair DetectiveSummaryThe Summary page displays a summary of the pass/fail status, DC-Voltage/Current and Isolation for each
SmartR™ FeaturesMaxTester Copper Test 127Pair DetectivePair Detective Cable SetupThe Cable Setup page allows you to set Cable Parameters for the Pair
SmartR™ Features128 MAX-610Pair DetectivePair Detective Threshold SettingsThe Threshold Settings page allows you to set the Pair Detective Threshold S
SmartR™ FeaturesMaxTester Copper Test 129Pair DetectiveMultimeterThe Pair Detective Multimeter page displays read-only results and the P/F (pass/fail)
SmartR™ Features130 MAX-610Pair DetectiveThe previous 2 parameters have 2 modes of operation: Auto is the default mode upon loading the test page. TD
SmartR™ FeaturesMaxTester Copper Test 131Pair Detective Pan - use left/right arrow keys to pan the x-axis and the up/down arrow keys to pan the y-axi
Introducing the MaxTester MAX-6106 MAX-610Cable ConnectionsSecondary Tip/A wire of phone lineSecondary Ring/B wire of phone lineShield of phone linePr
SmartR™ Features132 MAX-610Pair DetectiveCable SetupThe Cable Setup page allows you to set Cable Parameters for the TDR test. Cable Type allows you t
SmartR™ FeaturesMaxTester Copper Test 133Pair Detective Result DetailsPair Detective Result DetailsSummaryThe read-only Summary page displays the cabl
SmartR™ Features134 MAX-610Pair Detective Result DetailsMultimeterThe read-only Multimeter page displays detailed results saved from running the Pair
SmartR™ FeaturesMaxTester Copper Test 135FaultMapperFaultMapperThe FaultMapper test allows you to locate and identify service-affecting line faults us
SmartR™ Features136 MAX-610FaultMapperOpen and the distance to Open is displayed and represented using X in the graph. Test Status displays the curre
SmartR™ FeaturesMaxTester Copper Test 137FaultMapper Attenuation @ 300 kHz read-only entry is a value for the reduction in signal strength or inserti
SmartR™ Features138 MAX-610FaultMapperFaultMapper Result DetailsThe Result Details read-only page displays the test results in text and graphical form
SmartR™ FeaturesMaxTester Copper Test 139FaultMapperResult Details Cable SetupThe Cable Setup page in the Result Details allows you to view the Cable
SmartR™ Features140 MAX-610FaultMapperFaultMapper Profile DetailsThe Profile Details page displays read-only FaultMapper Test Parameters. Profile Nam
MaxTester Copper Test 1419 Noise TestsThe purpose of the noise tests is to perform VF (voice frequency)/WB (wideband) noise and level measurements.Not
Introducing the MaxTester MAX-610MaxTester Copper Test 7Cable ConnectionsWARNINGA 50 to 500 Vcc limited power source may be present on connector R/T/R
Noise Tests142 MAX-610VF NoiseVF NoiseThe VF Noise test allows you to measure the amount of unwanted or disturbing energy introduced into a loop from
Noise TestsMaxTester Copper Test 143VF NoiseTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2. Press
Noise Tests144 MAX-610VF NoiseResult DetailsThe Results Details read-only page displays the VF Noise value and the pass/fail status.
Noise TestsMaxTester Copper Test 145Power InfluencePower InfluenceThe Power Influence test allows you to view the effects of interference from a 50 Hz
Noise Tests146 MAX-610Power Influence Zoom references the middle of the x/y axis and not the cursor position. Press the arrow keys as follows: Right
Noise TestsMaxTester Copper Test 147Power InfluencePower Influence Threshold SettingsThe Threshold Settings page allows you to set the Threshold Power
Noise Tests148 MAX-610VF Impulse NoiseVF Impulse NoiseThe VF Impulse Noise test allows you to measure voice frequency impulse noise on the circuit und
Noise TestsMaxTester Copper Test 149VF Impulse NoiseTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.
Noise Tests150 MAX-610VF Impulse NoiseVF Impulse Noise Threshold SettingsThe Threshold Settings page allows you to set the VF Impulse Noise Threshold
Noise TestsMaxTester Copper Test 151VF Impulse NoiseResult DetailsThe Results Details read-only page displays the High, Mid, Low VF Impulse Noise Coun
Introducing the MaxTester MAX-6108 MAX-610ConventionsConventionsBefore using the product described in this guide, you should understand the following
Noise Tests152 MAX-610WB PSD NoiseWB PSD NoiseThe wideband power spectral density (PSD) noise test measures the noise energy at a point in a noise spe
Noise TestsMaxTester Copper Test 153WB PSD Noise Cursor - press the left/right arrow keys to decrease/increase the values by moving the cursor. Press
Noise Tests154 MAX-610WB PSD Noise Landscape Mode function key allows you to view the test results in landscape mode. Rotating the unit clockwise or
Noise TestsMaxTester Copper Test 155WB PSD NoiseTo select the parameter values in Portrait or Landscape modes:1. Press the up/down arrow keys to highl
Noise Tests156 MAX-610WB PSD NoiseResult DetailsThe Results Details read-only page displays the WB PSD Noise test results, in text and graphical forma
Noise TestsMaxTester Copper Test 157WB Impulse NoiseWB Impulse NoiseThe wideband impulse noise test allows you to measure impulse noise on the circuit
Noise Tests158 MAX-610WB Impulse Noise Result displays the Count, Detection Level, Elapsed Time, and pass/fail status which is periodically refreshed
Noise TestsMaxTester Copper Test 159WB Impulse NoiseWB Impulse Noise Threshold SettingsThe Threshold Settings page allows you to set the WB Impulse No
Noise Tests160 MAX-610WB Impulse NoiseResult DetailsThe Results Details read-only page displays the WB Impulse Noise Count, Detection Level, and pass/
Noise TestsMaxTester Copper Test 161NEXTNEXTThe NEXT test measures the Near End Crosstalk (NEXT) between 2 pairs of cables. The test transmits a signa
MaxTester Copper Test 92 Safety InformationWARNINGThe use of controls, adjustments and procedures other than those specified herein may result in expo
Noise Tests162 MAX-610NEXT Hookup Diagram button opens a Confirmation page displaying how to connect your cables at the beginning of the test. When F
Noise TestsMaxTester Copper Test 163NEXTHowever, you can check the connection diagram at any time by pressing the Hookup Diagram button. In this case,
Noise Tests164 MAX-610NEXTTo select the Spot parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2. Press the left/rig
Noise TestsMaxTester Copper Test 165NEXTSpot Result DetailsThe Spot Results Details read-only page displays the saved pass/fail status, NEXT and Frequ
Noise Tests166 MAX-610NEXTSpectrumSpectrum is a snapshot mode of operation similar to WB Attenuation. The test makes one measurement of the crosstalk
Noise TestsMaxTester Copper Test 167NEXT Proceed button closes the hookup diagram prompt and starts the test. Cancel button closes the hookup diagra
Noise Tests168 MAX-610NEXT Threshold Settings button opens a new page that allows you to set the NEXT Spectrum Threshold. Select Graph button change
Noise TestsMaxTester Copper Test 169NEXTTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2. Press the
Noise Tests170 MAX-610NEXTSpectrum Result DetailsThe Spectrum Results Details read-only page displays the pass/fail status and test results in graphic
Noise TestsMaxTester Copper Test 171NEXTNEXT Results Profile DetailsThe NEXT Profile Details page displays detailed read-only test thresholds and para
Safety Information10 MAX-610Electrical Safety InformationElectrical Safety InformationThe AC adapter/charger provided with this unit (18 W/9 V) is spe
MaxTester Copper Test 17310 Frequency TestsThe purpose of the frequency tests is to perform VF (voice frequency) and WB (wide band) level measurements
Frequency Tests174 MAX-610VF/AC BalanceVF/AC BalanceThe VF/AC Balance test allows you to check that the VF longitudinal balance ratio for the twisted
Frequency TestsMaxTester Copper Test 175VF/AC BalanceNote: The selected Standard in Setup/Application Settings determines the name of the frequency te
Frequency Tests176 MAX-610VF/AC BalanceActive Result DetailsThe Active Results Details read-only page displays the VF/AC Balance value and the pass/fa
Frequency TestsMaxTester Copper Test 177VF/AC Balance Result displays the Passive pass/fail status, Power Influence, VF Noise, and VF/AC Balance valu
Frequency Tests178 MAX-610VF/AC BalanceVF/AC Balance Passive Threshold SettingsThe Threshold Settings page allows you to set the Passive VF/AC Balance
Frequency TestsMaxTester Copper Test 179VF/AC BalancePassive Result DetailsThe Passive Results Details read-only page displays the Passive pass/fail s
Frequency Tests180 MAX-610WB BalanceWB BalanceThe wideband balance test ensures that the balance ratio for the twisted pair complies with applicable s
Frequency TestsMaxTester Copper Test 181WB Balance Cursor - press the left/right arrow keys to decrease/increase the values by moving the cursor. Pre
Safety InformationMaxTester Copper Test 11Equipment RatingsEquipment RatingsEquipment RatingsTemperature Operation Storage 0 °C to 40 °C (32 °F to
Frequency Tests182 MAX-610WB Balance Landscape Mode function key allows you to view the test results in landscape mode. Rotating the unit clockwise o
Frequency TestsMaxTester Copper Test 183WB BalanceTo select the parameter values in Portrait or Landscape modes:1. Press the up/down arrow keys to hig
Frequency Tests184 MAX-610WB BalanceResult DetailsThe Results Details displays a graph of the Marginal and Good wideband balance results, and pass/fai
Frequency TestsMaxTester Copper Test 185WB AttenuationWB AttenuationAttenuationThe WB (wideband) single-ended attenuation test allows you to calculate
Frequency Tests186 MAX-610WB Attenuation Zoom references the middle of the x/y axis and not the cursor position. Press the arrow keys as follows: Rig
Frequency TestsMaxTester Copper Test 187WB AttenuationWB Attenuation Threshold SettingsThe Threshold Settings page allows you to set the WB Attenuatio
Frequency Tests188 MAX-610WB AttenuationCable SetupThe Cable Setup page allows you to set the Cable Type and Cable Temperature for the WB Attenuation
Frequency TestsMaxTester Copper Test 189WB AttenuationTo select the parameter values:1. Press the up/down arrow keys to highlight the desired paramete
Frequency Tests190 MAX-610WB Attenuation Select Graph button changes to Graph Selected when pressed and opens a new selection of function keys which
Frequency TestsMaxTester Copper Test 191WB AttenuationResult Details Cable SetupThe Cable Setup page in the Result Details allows you to view the Cabl
Copyright Informationii MAX-610Copyright InformationCopyright © 2012–2014 EXFO Inc. All rights reserved. No part of this publication may be reproduced
Frequency Tests192 MAX-610Load CoilsLoad CoilsThe Load Coils test allows you to detect the presence of load coils, which are detrimental to the use of
Frequency TestsMaxTester Copper Test 193Load Coils Select Graph button changes to Graph Selected when pressed and opens a new selection of function k
Frequency Tests194 MAX-610Load CoilsTDRThe Load Coils TDR function provides a shortcut to the TDR test. A dialogue box opens, warning that you are abo
Frequency TestsMaxTester Copper Test 195Locator ToneLocator ToneWhen Locator Tone is selected from the Frequency Tests menu, a 577 Hz signal and a 983
Frequency Tests196 MAX-610Locator ToneTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2. Press the l
Frequency TestsMaxTester Copper Test 197TX/RX ToneTX/RX ToneThe TX/RX Tone tests allow you to measure the frequencies and levels of outgoing and incom
Frequency Tests198 MAX-610TX/RX ToneTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2. Press the lef
Frequency TestsMaxTester Copper Test 199TX/RX ToneReceive ToneThe Receive Tone (RX) tab allows you to configure and run a receive tone test, which mea
Frequency Tests200 MAX-610TX/RX ToneResult DetailsThe Results Details read-only page displays the saved receive tone or RX VF/WB Level and VF/WB Frequ
MaxTester Copper Test 20111 TDRThe TDR test first attempts to find the length of the circuit and then searches all ranges from shortest to longest for
MaxTester Copper Test 133 Getting Started with the MaxTesterTurning the Unit On/OffWhen you turn the unit on, you may use it immediately under normal
TDR202 MAX-610Continuous Pulse Width is a non-editable value that is updated dependent on whether the parameters are set to Auto or manual. Dual Tra
TDRMaxTester Copper Test 203Continuous Test Status displays the current state of measurement or an error message. Load Trace function key opens a ne
TDR204 MAX-610Continuous Parameters displays a small strip window when selected allowing you to change the Range and Gain values from a list of optio
TDRMaxTester Copper Test 205Cable SetupCable SetupThe Cable Setup page allows you to set Cable Parameters for the TDR test. These values can be set in
TDR206 MAX-610Load TraceLoad TraceThe Load Trace function allows you to load a saved trace. The tab opens a page listing previously saved TDR tests by
TDRMaxTester Copper Test 207Result DetailsResult DetailsThe Results Details page displays the TDR test result cable parameters and the distance to the
TDR208 MAX-610Result Details Cursor - press the left/right arrow keys to decrease/increase the values by moving the cursor. Press and hold the left/r
TDRMaxTester Copper Test 209Result DetailsThis mode generates the following function keys: Portrait Mode is used to change the screen orientation fro
TDR210 MAX-610Result DetailsTo select the parameter values in Portrait or Landscape modes:1. Press the up/down arrow keys to highlight the desired par
TDRMaxTester Copper Test 211Result DetailsLoad TraceThe Load Trace function allows you to load a saved trace. The tab opens a page listing previously
Getting Started with the MaxTester14 MAX-610Using Menus and KeypadTo enter suspend mode:Press for about 2 seconds. The MaxTester will stay in suspen
TDR212 MAX-610TDR Profile DetailsTDR Profile DetailsThe Profile Details page displays read-only TDR Test Parameters. Profile Name is the file name of
MaxTester Copper Test 21312 RFLResistance fault locator (RFL) testing is a powerful means to locate resistive faults such as shorts, grounds, and batt
RFL214 MAX-610Single Pair Current Test displays the test being measured. When FED is Enabled, the FED icon and numeric state are displayed beside the
RFLMaxTester Copper Test 215Separate Good Pair Fault Status displays the status of the RFL test. Test Status displays the current state of measureme
RFL216 MAX-610Separate Good PairNote: Results are more accurate but less forgiving than a 2-wire setup because the 4-wire setup requires you to connec
RFLMaxTester Copper Test 217Separate Good Pair There is a strap, but there is a high resistance fault or open in the cable. The connection (leads or
RFL218 MAX-610RFL Cable SetupRFL Cable SetupThe Cable Setup page allows you to set cable parameters for an RFL test. Settings are shared by both Singl
RFLMaxTester Copper Test 219RFL Cable SetupTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter.2. Press
RFL220 MAX-610Result DetailsResult DetailsSingle PairThe Results Details read-only page displays the Single Pair RFL results using text and a connecti
RFLMaxTester Copper Test 221Result DetailsCable SetupThe Cable Setup page displays the cable parameters for each section used while running the RFL te
Getting Started with the MaxTesterMaxTester Copper Test 15KeypadKeypad Power button on the lower left side of the unit is used to power the unit on a
MaxTester Copper Test 22313 Copper Auto TestsMain MenuAuto Test allows you to automatically run tests used in pre-qualification, installation, and mai
Copper Auto Tests224 MAX-610POTS Auto TestPOTS Auto TestThe purpose of the POTS Auto Test is to detect the loop current and measure the voice frequenc
Copper Auto TestsMaxTester Copper Test 225POTS Auto Test Phone Book Parameters: Phone Book Group allows you to select the Group # from a list of pho
Copper Auto Tests226 MAX-610POTS Auto TestPOTS Auto Test Threshold SettingsThe Threshold Settings page allows you to set the POTS Auto Test Threshold
Copper Auto TestsMaxTester Copper Test 227POTS Auto TestResult DetailsThe Results Details read-only page displays the number dialed and its status, me
Copper Auto Tests228 MAX-610User Auto TestUser Auto TestUser Auto Test runs a range of different user-defined tests that compare measured results agai
Copper Auto TestsMaxTester Copper Test 229User Auto TestTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parame
Copper Auto Tests230 MAX-610User Auto Test Resistance uses DC current to measure the opposition to flow, or resistance, between each of the lead comb
Copper Auto TestsMaxTester Copper Test 231User Auto TestTo select the tests:1. Press the up/down arrow keys to scroll through all the tests and highli
Copper Auto Tests232 MAX-610User Auto TestUpload/Save ResultThe Upload/Save Result tab allows you to save/upload/export Auto Test results, using the u
Copper Auto TestsMaxTester Copper Test 233User Auto Test Result File Name previews the result file name which consists of the Circuit ID, date and ti
Copper Auto Tests234 MAX-610User Auto TestTo set parameter values and save results:1. Press the left/right and up/down arrow keys to highlight the des
Copper Auto TestsMaxTester Copper Test 235User Auto TestMultimeter 2 ResultThe Multimeter 2 Result page displays the following results: Resistive Bal
Copper Auto Tests236 MAX-610User Auto TestNoise Result2The Noise Result2 page displays the following results and pass/fail status: WB PSD Noise - Max
Copper Auto TestsMaxTester Copper Test 237User Auto TestFrequency ResultThe Frequency Result page displays the following results: VF/AC Balance (Acti
Copper Auto Tests238 MAX-610User Auto Test Select Graph button changes to Graph Selected when pressed and opens a new selection of function keys whic
Copper Auto TestsMaxTester Copper Test 239User Auto TestTDR Result Cable SetupThe Cable Setup page allows you to configure and view the Cable Paramete
Copper Auto Tests240 MAX-610Result DetailsResult DetailsThe Result Details for User Auto Test display all the saved results presented during the test.
Copper Auto TestsMaxTester Copper Test 241Result DetailsCable SetupThe Cable Setup page displays read-only parameters of the cable used in the Auto Te
MaxTester Copper Test 174 Setting Up the MaxTester MAX-610HomeHome presents the main menu page which allows you to navigate between Copper Test and Sy
Copper Auto Tests242 MAX-610Profile DetailsProfile DetailsProfile Details contains the details of the Test Selection settings for User Auto Test. If F
Copper Auto TestsMaxTester Copper Test 243Profile DetailsTest ParametersThe Test Parameters page displays read-only parameter details of all tests.Mul
Copper Auto Tests244 MAX-610Profile DetailsNoise 2 ParameterThe Noise 2 Parameter page displays the profile details of the parameter values for the WB
Copper Auto TestsMaxTester Copper Test 245Profile DetailsTest ThresholdsThe Test Thresholds pages display read-only threshold values for each test.Mul
Copper Auto Tests246 MAX-610Profile DetailsNoise ThresholdThe Noise Threshold page displays the Test Thresholds and limits for the following tests: V
MaxTester Copper Test 24714 MaintenanceGeneral MaintenanceThe MaxTester has been designed to be a rugged and lightweight piece of test equipment. The
Maintenance248 MAX-610Recalibrating the UnitRecalibrating the UnitEXFO manufacturing and service center calibrations are based on the ISO/IEC 17025 st
MaintenanceMaxTester Copper Test 249Recalibrating the UnitTo help you with calibration follow-up, EXFO provides a special calibration label that compl
Maintenance250 MAX-610BatteryBatteryThe MAX-610 is equipped with a Lithium-ion battery.When fully charged, the battery should provide between 3 and 10
MaintenanceMaxTester Copper Test 251BatteryBattery CalibrationIn order to optimize the battery gas gauge accuracy, a battery calibration procedure is
Setting Up the MaxTester MAX-61018 MAX-610System SettingsSystem SettingsSystem Settings presents a menu of items to setup the unit. Display & Lan
Maintenance252 MAX-610Recycling and Disposal (Applies to European Union Only)3. Remove the new battery from its package. Keep the package for future u
MaxTester Copper Test 25315 TroubleshootingSolving Common ProblemsThe table below presents common problems and their solution.Problem Possible Cause S
Troubleshooting254 MAX-610Solving Common ProblemsThe unit is not responding. Shut down the unit, as above. Turn the unit on again to reset it.Probl
TroubleshootingMaxTester Copper Test 255LED StatusesLED StatusesThe power and battery LEDs are used to indicate specific statuses of your unit. If you
Troubleshooting256 MAX-610Contacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or technical suppo
TroubleshootingMaxTester Copper Test 257TransportationTransportationMaintain a temperature range within specifications when transporting the unit. Tra
MaxTester Copper Test 25916 WarrantyGeneral InformationEXFO Electro-Optical Engineering Inc. (EXFO) warrants this equipment against defects in materia
Warranty260 MAX-610LiabilityLiabilityEXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any fail
WarrantyMaxTester Copper Test 261ExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of any of its products at a
Setting Up the MaxTester MAX-610MaxTester Copper Test 19Display and LanguageDisplay and LanguageTo fit your environment, you may adjust the LCD bright
Warranty262 MAX-610Service and RepairsService and RepairsEXFO commits to providing product service and repair for five years following the date of pur
WarrantyMaxTester Copper Test 263EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact your nearest
MaxTester Copper Test 265A Technical SpecificationsIMPORTANTThe following technical specifications can change without notice. The information presente
Technical Specifications266 MAX-610COPPER SPECIFICATIONS a, b, c (continued)Isolation resistance (stress/leakage) (continued)Source 50 to 125 VDC (cur
Technical SpecificationsMaxTester Copper Test 267COPPER SPECIFICATIONS a, b, c (continued)Power spectral density (PSD) Test type Continuous with peak-
Technical Specifications268 MAX-610GENERAL SPECIFICATIONSDisplay TFT LCD with backlight152 mm (6 in) diagonal800 x 480 resolution, WVGATest connection
IndexMaxTester Copper Test 269IndexAAC requirements ... 11after-sales service ...
Index270 MAX-610TTDR ... 230technical specifications ... 265technica
NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT
Setting Up the MaxTester MAX-61020 MAX-610Date and TimeDate and TimeWhen saving results, the unit also saves the corresponding Date and Time.You can e
MARKING REQUIREMENTS㪖㽷尐㻑Productℶ❐Environmental protection use period (years)䘾⬒≬㔳∎䞷㦮棟 ( )Logo㪖㉦This E;)2 product㦻 EXFO ℶ❐10Batterya䟄㻯aa. If applicabl
www.EXFO.com · [email protected]/N: 1067073CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-
Setting Up the MaxTester MAX-610MaxTester Copper Test 21PowerPowerBattery StatusThe BATTERY Status pane indicates the current power level for the batt
ContentsMaxTester Copper Test iiiContentsCopyright Information ...
Setting Up the MaxTester MAX-61022 MAX-610PowerNote: Setting the DC IN suspend timeout to the lowest value and not to Never ensures the unit enters su
Setting Up the MaxTester MAX-610MaxTester Copper Test 23Power Aborted displays when the calibration procedure has been started but the DC plug was re
Setting Up the MaxTester MAX-61024 MAX-610Software OptionsSoftware OptionsCopper OptionsThis screen lists all the Copper Configured Options which are
Setting Up the MaxTester MAX-610MaxTester Copper Test 25InformationInformationAbout EXFOThe About tab contains contact information should you require
Setting Up the MaxTester MAX-61026 MAX-610Upload SetupUpload SetupUpload EnableThe Upload Enable function allows you to upload your result files using
Setting Up the MaxTester MAX-610MaxTester Copper Test 27Upload Setup Ethernet is the default upload and if selected, displays ethernet icon in the
Setting Up the MaxTester MAX-61028 MAX-610Upload SetupFTP SetupThe FTP Setup function allows you to configure the file transfer information using the
Setting Up the MaxTester MAX-610MaxTester Copper Test 29Upload SetupTo configure the setup options:1. Press the up/down arrows to select the desired p
Setting Up the MaxTester MAX-61030 MAX-610Upload Setup Select Other Network button opens a new page allowing you to search for a specific network. F
Setting Up the MaxTester MAX-610MaxTester Copper Test 31Upload SetupSelect NetworkThe Select Network page allows you to search for a specific Wi-Fi ne
Contentsiv MAX-6105 Setting Up Copper Tests ...35Copper Test Main Menu ...
Setting Up the MaxTester MAX-61032 MAX-610Upload SetupEthernet SetupThe Ethernet Setup function allows you to configure the line and access modes, etc
Setting Up the MaxTester MAX-610MaxTester Copper Test 33Upload SetupThe following parameters are available only when Access Mode is Static. IP Addres
MaxTester Copper Test 355 Setting Up Copper TestsThe MaxTester is designed to test basic twisted pair quality, identify and locate faults, and trouble
Setting Up Copper Tests36 MAX-610Test ConfigurationTest ConfigurationBefore performing copper tests, you can set up the software settings and values f
Setting Up Copper TestsMaxTester Copper Test 37Test Configuration Copy to USB allows you to copy all profiles found in the internal memory to an exte
Setting Up Copper Tests38 MAX-610Test ConfigurationTo save a profile, use one of the following function keys: Save allows you to save to the currentl
Setting Up Copper TestsMaxTester Copper Test 39Test ConfigurationProfile Details Main MenuYou can view any of your saved profiles on the MaxTester MAX
Setting Up Copper Tests40 MAX-610Test ConfigurationTo navigate between the test profiles:1. Press the up/down left/right arrow keys on the keypad to s
Setting Up Copper TestsMaxTester Copper Test 41Test ConfigurationFrequency Tests Profile DetailsThe profile details Frequency Tests main menu allows y
ContentsMaxTester Copper Test v10 Frequency Tests ... 173Frequen
Setting Up Copper Tests42 MAX-610Test ConfigurationDelete ProfileDelete Profile lists all profiles found on the internal memory except the default pro
Setting Up Copper TestsMaxTester Copper Test 43SetupSetupThe Setup function allows you to set up parameters common to all tests.To access the Setup fu
Setting Up Copper Tests44 MAX-610Phone BookPhone BookThe Phone Book menu presents a selection of functions which allow you to manage the groups of pho
Setting Up Copper TestsMaxTester Copper Test 45Phone BookSelect Group/EntryThe page lists entries by Group ID and Entry Name/Type. There is 1 group of
Setting Up Copper Tests46 MAX-610Phone Book Type displays the following list of values: Milliwatt tone Drop battery Quiet line - (for additional
Setting Up Copper TestsMaxTester Copper Test 47Phone BookAdd GroupThe Add Group page allows you to add a new group entry into the Phone Book using the
Setting Up Copper Tests48 MAX-610Phone BookClone GroupThe Clone Group page allows you to copy the details of an existing entry to a new group entry in
Setting Up Copper TestsMaxTester Copper Test 49Phone BookDelete GroupThe Delete Group page allows you to delete a group entry from the Phone Book. The
Setting Up Copper Tests50 MAX-610Phone BookLoad Phone BookThe Load Phone Book page allows you to import a phone book. The page displays the file name
Setting Up Copper TestsMaxTester Copper Test 51Phone BookSave Phone BookThe Save Phone Book page allows you to save or export a phone book. Save File
Contentsvi MAX-61016 Warranty ...259General Informati
Setting Up Copper Tests52 MAX-610Dialer FunctionDialer FunctionThe Dialer function provides a dial-up path from the MAX-610 to another tester (or quie
Setting Up Copper TestsMaxTester Copper Test 53Dialer Function Enter Number displays the telephone number entered or selected from the Recent Dialed
Setting Up Copper Tests54 MAX-610Dialer FunctionEnter NumberThe Enter Number box is where you enter the phone number you wish to dial. To enter a phon
Setting Up Copper TestsMaxTester Copper Test 55Dialer FunctionRecent Dialed NumbersThe Select Number page lists a maximum of 8 recently dialed telepho
Setting Up Copper Tests56 MAX-610Dialer FunctionAdd to Phone BookThe Add Group page allows you to add a new group entry into the Phone Book using the
Setting Up Copper TestsMaxTester Copper Test 57Cable BookCable BookThe Cable Book menu allows you to select, add, clone, and delete a cable, as well a
Setting Up Copper Tests58 MAX-610Cable BookCable DetailsThe Cable Details page allows you to view the cable parameter details of the currently highlig
Setting Up Copper TestsMaxTester Copper Test 59Cable BookTo view and modify the cable details:1. Press the up/down arrow keys to highlight the desired
Setting Up Copper Tests60 MAX-610Cable Book Attenuation @ 300 kHz allows you to specify a value for the reduction in signal strength or insertion los
Setting Up Copper TestsMaxTester Copper Test 61Cable BookClone CableThe Clone Cable page allows you to copy the cable details of an existing entry to
Certification InformationMaxTester Copper Test viiCertification InformationNorth America Regulatory StatementThis unit was certified by an agency appr
Setting Up Copper Tests62 MAX-610Cable BookDelete CableThe Delete Cable page allows you to delete a cable entry from the Cable Book. The page lists al
Setting Up Copper TestsMaxTester Copper Test 63Application SettingsApplication SettingsBefore executing the copper tests, set up the software settings
Setting Up Copper Tests64 MAX-610Application Settings Test Startup Mode lists the test startup type: Auto (default) automatically starts a test when
Setting Up Copper TestsMaxTester Copper Test 65Application SettingsStandardThe Standard tab allows you to set unit parameter values composed of the fo
Setting Up Copper Tests66 MAX-610Application Settings Label CustomizationConnection lists the type of cable connection: T-R-G or A-B-E. Test Paramet
Setting Up Copper TestsMaxTester Copper Test 67Application SettingsIdentificationThe Identification tab allows you to preset values to identify each s
Setting Up Copper Tests68 MAX-610Application SettingsTo select the parameter values:1. Press the up/down arrow keys to highlight the desired parameter
Setting Up Copper TestsMaxTester Copper Test 69Application SettingsFile NameThe File Name tab sets up the standard configuration for automatically nam
Setting Up Copper Tests70 MAX-610Application SettingsChange OrderChange Order page allows you to change the order of the entries in the file name.To c
Setting Up Copper TestsMaxTester Copper Test 71Application SettingsBuzzerThe Buzzer tab allows you to configure values for the buzzer settings. Howeve
European Community Declaration of Conformityviii MAX-610European Community Declaration of Conformity Page 1 of 1 DECLARATION OF CONFORMITY Applica
Setting Up Copper Tests72 MAX-610Test Lead CompensationTest Lead CompensationTest lead compensation is required for some of the copper tests so as not
Setting Up Copper TestsMaxTester Copper Test 73FED SetupFED SetupFED Setup is an option enabled feature that implements Teletech TS125 Remote FED (far
Setting Up Copper Tests74 MAX-610FED Setup2. For Open, set the FED so that the T-R/A-B wires connected to the customer side of the FED are open circui
Setting Up Copper TestsMaxTester Copper Test 75FED SetupThe FED Setup tab displays the following parameters: FED sets the default FED States for the
Setting Up Copper Tests76 MAX-610FED SetupNote: For all FED States other than Pass Through/Exchange Connect, the Dialer tab is disabled. If the dialer
Setting Up Copper TestsMaxTester Copper Test 77FED SetupMultimeterThe Multimeter tab lists the default FED States set for all multimeter tests.NoiseTh
Setting Up Copper Tests78 MAX-610FED SetupFrequencyThe Frequency tab lists the default FED States set for all frequency tests.OtherThe Other tab displ
Setting Up Copper TestsMaxTester Copper Test 79Saving ResultsSaving ResultsSave ResultYou can save a snapshot of test results into a result file durin
Setting Up Copper Tests80 MAX-610Saving Results Save Result Select Result File button displays a list of existing file names where you can save your
Setting Up Copper TestsMaxTester Copper Test 81Saving ResultsTo set parameter values and save results:1. Press the left/right and up/down arrow keys t
MaxTester Copper Test 11 Introducing the MaxTester MAX-610The MaxTester MAX-610 is a handheld device designed to qualify and troubleshoot the copper-l
MaxTester Copper Test 836 Reading Saved Copper Test ResultsRead/Upload ResultYou can view or export any of your saved results with the MaxTester Coppe
Reading Saved Copper Test Results84 MAX-610Read Result MenuRead Result MenuThe Read Result menu allows you to view saved test results with the followi
Reading Saved Copper Test ResultsMaxTester Copper Test 85Read Result MenuSummaryThe results Summary page displays pass/fail status, general and identi
Reading Saved Copper Test Results86 MAX-610Read Result Menu Function keys: Save keeps any current changes with the current file name. Save As saves
Reading Saved Copper Test ResultsMaxTester Copper Test 87Read Result MenuResult DetailsThe Results Details page allows you to view measured results fo
Reading Saved Copper Test Results88 MAX-610Read Result MenuPhone BookThe Phone Book page summarizes the Phone Book details when loading a results file
Reading Saved Copper Test ResultsMaxTester Copper Test 89UploadUploadThe Upload page allows you to upload the saved results of User Auto tests only to
Reading Saved Copper Test Results90 MAX-610ExportExportThe Export page allows you to select a File Name or All files previously saved and export the r
Reading Saved Copper Test ResultsMaxTester Copper Test 91Export8. Press the left/right arrow keys to select the desired format OR9. Press to display