Traffic Generation & Monitoring
Ethernet Test Set 145
Stream Configuration
The possible values are shown as follows:
³ If DS is selected, go to the next field to
enter the hexadecimal code 00 to FF or
go to the field underneath to enter the
binary code.
Parameter Value Bit
Precedence 000 (Routine), 001 (Priority), 010 (Immediate),
011 (Flash), 100 (Flash Override),
101 (CRITIC/ECP), 110 (Internet Control),
111 (Network Control)
Default: 000 (Routine)
1-3
Throughput Normal / High (0/1)
Default: Normal
4
Monetary Cost Normal / Low (0/1)
Default: Normal
5
Delay Normal / Low (0/1)
Default: Normal
6
Reliability Normal / High (0/1)
Default: Normal
7
Reserved bit 0 or 1
Default: 0
8