SCPI-Befehlsreferenz
378 Serie FTB-7000
Product-Specific Commands—Description
:CONFigure[1..n]:ACQuisition:
DURation?
Description This query returns the current duration setting.
*RST reverts this setting to default value.
Syntax :CONFigure[1..n]:ACQuisition:DURation?[<wsp
>MINimum|MAXimum|DEFault]
Parameter(s) Parameter 1:
The program data syntax for the first parameter is
defined as a <CHARACTER PROGRAM DATA>
element. The allowed <CHARACTER PROGRAM
DATA> elements for this parameter are:
MINimum|MAXimum|DEFault.
MINimum is used to retrieve the instrument's
lowest supported value.
MAXimum is used to retrieve the instrument's
highest supported value.
DEFault is used to retrieve the instrument's
default value.
Response Syntax <Duration>