Creating and Starting a Test Case
Ethernet and Fibre Channel Application 103
Ethernet TCP Throughput Test Case
4. Press Test, TCP Throughput, and Configuration.
4a. Select Remote as the TCP Mode.
4b. Enter the IP address of the local module in the Listening IP
Address field.
Create the test on the local module as follow:
1. On the local module, proceed with the test creation as described
above (start with step 1 on page 101 up to step 4 inclusively). However,
in step 4 do the following:
1a. Select Local as the TCP Mode.
1b. Enter the IP address of the remote module in the Remote IP
Address field.
2. For additional configuration parameters, refer to TCP Throughput
Configuration on page 309.
3. Press the Start button to start the test. Pressing the Start button while
in test setup window, will automatically switch to the tab TCP
Throughput Results on page 313.
4. For additional results, refer to TCP Throughput Results on page 313.